While recent advancements in next-generation sequencing technology have greatly improved research in whole transcriptome RNA-seq, several challenges still remain, stemming from the complexity inherent in such large-scale sequencing. The large dynamic range of the transcriptome often means that a few highly abundant transcripts account for the majority of sequencing reads while only representing a small percentage of RNAs. In contrast, less-abundant transcripts (representing a majority of RNAs) account for only a small percentage of sequencing reads (Jiang et al. 2011). Targeted RNA-seq aims to overcome this problem by improving sequence coverage of transcripts of interest that may be present in low amounts, thus saving costs and simplifying analysis. This enrichment enables the capture of information about transcripts that would otherwise be missed or would require a much greater number of sequencing reads to be detected, including chimeric gene fusions, transcript isoforms, and splice variants (reviewed in Byron et al. 2016).
SMARTer Target RNA Capture for Illumina provides a streamlined, sensitive method for enriching for transcripts of interest from total RNA prior to first-strand cDNA synthesis. Target-specific probes are hybridized to transcripts of interest, the resulting RNA-DNA hybrids are captured with streptavidin-coated Capture Beads, and SMART-Seq v4 technology is used for first-strand cDNA synthesis. The Capture Beads have been specifically selected for their low adsorption of protein and nucleic acids, and lack of interference with downstream reactions. SMART-Seq v4 cDNA synthesis enables high sensitivity, low background, and ensures the production of full-length cDNAs.
Tech Note
Sensitive capture of full-length transcript information with targeted RNA-seq
Introduction
Results
Target-specific and sensitive RNA capture
In order to assess the ability to enrich for targeted genes, SMART-Seq v4 cDNA synthesis was performed on samples both with and without first carrying out the capture part of the protocol. In this manner, nine genes were targeted in four RNA samples, using 100 ng each of starting material. In general, targeted genes from each sample were enriched, often at the expense of highly expressed transcripts (e.g., GAPDH, ERCC-002) that were not targeted. By capturing genes of interest, 14–37% of sequencing reads were on-target compared with less than 0.1% with a no-capture protocol. This increase in the percentage of reads on target reduces the number of sequencing reads and overall costs required to obtain desired sequencing data, as compared to whole-transcriptome RNA-seq. The targeted enrichment also showed significantly better results for on-target reads when capture was part of the protocol. We have observed that genes with very low expression in certain RNA samples can result in fewer on-target reads for those transcripts being identified in those samples (e.g., ALK in RNA from KBM-7 cells and CDKN2A in RNA from K562 cells).
Identification of rare gene fusions at low sequencing depth
The highly sensitive targeted-enrichment protocol enables the detection of rare gene fusion events at low sequencing depth while targeting for only one of the gene fusion partners. For example, K562 cells are derived from chronic myelogenous leukemia and harbor a BCR-ABL1 fusion in about 30% of ABL1 transcripts (data not shown). In a sequencing library made from human brain RNA spiked with K562 RNA at 1%, it is expected that the BCR-ABL fusion would be present in less than 1 in 200 reads that map to the fusion locus. With the power of SMART technology for amplifying full-length transcript information and by using probes targeting only ABL1, this fusion was evident using a modest sequencing library of fewer than 2 million total mapped reads (data not shown).
Consistent enrichment and coverage across input levels
SMARTer Target RNA Capture for Illumina has been optimized across a range of input levels (10 ng–1 µg), as shown below. Human Brain Reference RNA (HBRR; Thermo Fisher Scientific) or Human Universal Reference RNA (HURR; Agilent) total RNA ranging from 100 pg to 1 µg was used as input for this kit, with 1 pmol of probes against 60 genes. The kit displayed strong capabilities in the percent of on-target reads, fold-enrichment, and the number of targeted genes identified.
The on-target percentage for HBRR and HURR samples was ~25% and ~45%, respectively. This variation is due to inherent differences between the two RNAs, with many reads mapping against mitochondrial sequences in HBRR, but not in HURR. The higher percentage of mitochondrial HBRR sequences is also observed in the no-capture control (NCC), indicating that it is a characteristic of HBRR in general. The number of target genes identified (out of 60) represents the number of targeted genes that had a read greater than one.
Enrichment led to a 90-fold increase over the no-capture control and was fairly similar for the two RNA types. 80% of the target genes were captured independent of sequencing depth. While there were less than one million reads for each sample, the data do not indicate a compromise in sensitivity, as a higher sequencing depth would not necessarily result in the identification of additional transcripts. For example, the 10-ng HBRR and HURR samples were run on a NextSeq with 150 x 150 paired-end reads, with ~100 million reads per sample (data not shown).The same libraries created from the 10-ng samples were also run on a MiSeq instrument, where the increase in sequencing depth improved the fraction of bases covered at a given depth, as expected, but only increased the number of target genes identified by one (HBRR) or two (HURR) transcripts. It is important to note that attaining 100% of on-target reads is nearly impossible regardless of sequencing depth, because the target region was set as the union of all possible transcript isoforms and not all isoforms are expressed for this RNA. Additionally, we expect that identification of some transcripts may be stochastic due to low expression level, low total RNA input, and/or insufficient sequencing depth.
Enriched targets maintain relative expression levels
Although the main goal of targeted transcript capture is to allow identification of transcripts with greater sensitivity, there has been some question as to whether it can maintain relative expression levels in a single sample or maintain differential expression between two samples. The Microarray Quality Control (MAQC) studies used TaqMan qPCR data to evaluate differential expression of ~1,000 genes between HURR and HBRR on microarray platforms. To evaluate this kit, the NGS expression data (expressed as FPKM) from the experiment above was compared against the TaqMan data. 17 of the 60 genes in the probe set also appear in the MAQC data.
There was a strong relationship between the orthogonal technologies, suggesting that the targeted capture method is maintaining similar relationships for differential expression ratios for these two RNA samples. Too few MAQC genes were captured for the 1-ng and 100-pg inputs so analysis was not possible.
Conclusions
SMARTer Target RNA Capture for Illumina is a targeted RNA-seq kit that leverages the sensitivity of SMART-Seq v4 technology to generate high-quality, full-length cDNA from enriched transcripts. The high level of sensitivity enables the detection of rare structural events such as gene fusions that might otherwise be missed in whole transcriptome RNA-seq, even at low sequencing depths. With lower sequencing depth required, analysis time and experimental costs are reduced. Performance is consistent across input levels and different RNA types, and relative expression levels are maintained post-enrichment.
Methods
Highly specific and sensitive RNA capture
Fold enrichment for nine genes from four different RNA samples was measured with and without targeted capture (but same RNA input and same number of PCR cycles). Each RNA sample input was 100 ng. ERCC Mix 1 was spiked into K562 RNA (BioChain Inc., Cat. No. R1255820-50) and HURR (Agilent, Cat. No. 740000), and ERCC Mix 2 was spiked into KBM-7 RNA (purified from cells) and Human Brain Total RNA (Cat. No. 636530). The genes of interest were targeted with 1 pmol of probe against 9 genes (~160 exons, ~55 kb total target region).
Sequencing libraries were run on an Illumina MiSeq (75 x 75 paired-end reads), and sequencing reads were aligned to the human reference GRCh38 release 23 (Gencode) with the TopHat or STAR aligner. The number of read counts were determined for each targeted gene after downsampling to the same number of reads (~2 M). The fold enrichment was calculated as the total number of sequencing reads against the target obtained after capture, divided by the number of sequencing reads obtained without capture. The percentage of on-target reads was calculated as the total number of sequencing reads against the targeted genes, divided by the number of uniquely mapped reads.
For the BCR-ABL1 fusion, K562 RNA was spiked into Human Brain Total RNA at 1% for 10 ng of combined RNA. 1 pmol probes against only ABL1 were used. Sequencing libraries were run on an Illumina MiSeq (75 x 75 paired-end reads), and sequencing reads were aligned to the human reference with the TopHat aligner and then downsampled to the same number of reads (~2 M). The number of reads to the fusion was determined with a custom script that directly queried reads for evidence of a translocation.
Consistent enrichment and coverage across input levels
HBRR (Thermo Fisher Scientific, Cat. No. AM6050) or HURR total RNA was used as input into the SMARTer Target RNA Capture for Illumina protocol, with amounts ranging from 100 pg to 1 µg. 1 pmol of probes against 60 genes were used (1,200 exons, ~0.46 Mb). Sequencing libraries were run on a MiSeq (75 x 75 paired-end reads), and sequencing reads were aligned with STAR to the GRCh38 release 23 with Gencode annotations. The number of read counts and FPKMs were determined for each targeted gene after downsampling to the same number of reads. The percentage of on-target reads was calculated as the total number of sequencing reads against the targeted genes, divided by the number of uniquely mapped reads as calculated by STAR. The fold-enrichment was calculated as the total number of sequencing reads against the target obtained after capture, divided by the number of sequencing reads obtained without capture. The target region was set as the union of all possible transcript isoforms and not all isoforms are expressed for this RNA. The duplicate rate ranged from 23–24% within the target region for the HBRR samples. Duplicate rates for given genes are related to the expression of those genes, was not correlated with input, and removal of the duplicates did not alter the results. For MAQC analysis, the log2 ratio of FPKMs from HURR/HBRR was plotted against the log2 of the ratio of HURR/HBRR derived from qPCR TaqMan probes.
References
Byron, S. A., Van Keuren-Jensen, K. R., Engelthaler, D. M., Carpten, J. D. & Craig, D. W. Translating RNA sequencing into clinical diagnostics: opportunities and challenges. Nat. Rev. Genet. 17, 257–271 (2016).
Jiang, L. et al. Synthetic spike-in standards for RNA-seq experiments. Genome Res. 21, 1543–1551 (2011).
Related Products
Takara Bio USA, Inc.
United States/Canada: +1.800.662.2566 • Asia Pacific: +1.650.919.7300 • Europe: +33.(0)1.3904.6880 • Japan: +81.(0)77.565.6999
FOR RESEARCH USE ONLY. NOT FOR USE IN DIAGNOSTIC PROCEDURES. © 2023 Takara Bio Inc. All Rights Reserved. All trademarks are the property of Takara Bio Inc. or its affiliate(s) in the U.S. and/or other countries or their respective owners. Certain trademarks may not be registered in all jurisdictions. Additional product, intellectual property, and restricted use information is available at takarabio.com.